Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Rev Port Cardiol (Engl Ed) ; 40(3): 153-164, 2021 Mar.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33676777

RESUMO

INTRODUCTION AND OBJECTIVES: In severe aortic stenosis (AS), the impact of aortic valve replacement (AVR) on left ventricular (LV) systolic function assessed by strain and measured by echocardiography or cardiac magnetic resonance (CMR) has been controversial. We aimed to investigate LV systolic myocardial function changes six months after AVR using global longitudinal (GLS), circumferential (GCS) and radial (GRS) strain derived from CMR imaging. METHODS: We included 39 severe AS patients (69.3±7.8 years; 61.5% male) with preserved LV ejection fraction (LVEF) who were recruited as part of the EPICHEART study and underwent successful AVR (aortic valvular area: 0.8 cm2 (IQR: 0.2) pre- to 1.8 cm2 (IQR:0.5) post-AVR). Structural and functional parameters were assessed at baseline and six months after AVR, including LV GRS, GCS and GLS analysis by CMR, using cine short-axial and two-, three-, and four-chamber long-axial view. Comparison between baseline and postoperative LV remodeling was performed using Student t-test and Wilcoxon test. RESULTS: At six-month follow-up, LV mass, end-diastolic and end-systolic volumes, stroke volume, cardiac output, lateral E/e', tricuspid annular plane systolic excursion, right ventricular (RV) S wave velocity, GLS [-15.6% (IQR: 4.39) to -13.7% (IQR: 4.62)] and GCS [-17.8±3.58% to -16.1±2.94%] reduced significantly, while LVEF and GRS remained unchanged and lateral e' velocity increased. CONCLUSIONS: Despite favorable reverse LV structural and diastolic functional remodeling six months following AVR, GLS and GCS assessed by CMR reduced compared to baseline, LVEF remained unchanged. The clinical utility and timing of assessment of postoperative strain changes as a marker of systolic function progression needs further research.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Volume Sistólico , Função Ventricular Esquerda
2.
Rev Port Cardiol (Engl Ed) ; 39(12): 705-717, 2020 Dec.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33261991

RESUMO

INTRODUCTION: The Portuguese National Registry of Transcatheter Aortic Valve Implantation records prospectively the characteristics and outcomes of transcatheter aortic valve implantation (TAVI) procedures in Portugal. OBJECTIVES: To assess the 30-day and one-year outcomes of TAVI procedures in Portugal. METHODS: We compared TAVI results according to the principal access used (transfemoral (TF) vs. non-transfemoral (non-TF)). Cumulative survival curves according to access route, other procedural and clinical variables were obtained. The Valve Academic Research Consortium-2 (VARC-2) composite endpoint of early (30-days) safety was assessed. VARC-2 predictors of 30-days and 1-year all-cause mortality were identified. RESULTS: Between January 2007 and December 2018, 2346 consecutive patients underwent TAVI (2242 native, 104 valve-in-valve; mean age 81±7 years, 53.2% female, EuroSCORE-II - EuroS-II, 4.3%). Device success was 90.1% and numerically lower for non-TF (87.0%). Thirty-day all-cause mortality was 4.8%, with the TF route rendering a lower mortality rate (4.3% vs. 10.1%, p=0.001) and higher safety endpoint (86.4% vs. 72.6%, p<0.001). The one-year all-cause mortality rate was 11.4%, and was significantly lower for TF patients (10.5% vs. 19.4%, p<0.002). After multivariate analysis, peripheral artery disease, previous percutaneous coronary intervention, left ventricular dysfunction and NYHA class III-IV were independent predictors of 30-day all-cause mortality. At one-year follow-up, NYHA class III-IV, non-TF route and occurrence of life-threatening bleeding predicted mortality. Kaplan-Meier survival analysis of the first year of follow-up shows decreased survival for patients with an EuroS-II>5% (p<0.001) and who underwent non-TF TAVI (p<0.001). CONCLUSION: Data from our national real-world registry showed that TAVI was safe and effective. The use of a non-transfemoral approach demonstrated safety in the short term. Long-term prognosis was, however, adversely associated with this route, with comorbidities and the baseline clinical status.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Portugal/epidemiologia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Health Qual Life Outcomes ; 18(1): 140, 2020 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-32410687

RESUMO

BACKGROUND: Health-related quality of life (HRQoL) is impaired in patients with stable angina but patients often present with other forms of chest pain. The aim of this study was to compare the pre-diagnostic HRQoL in patients with suspected coronary artery disease (CAD) according to angina type, gender, and presence of obstructive CAD. METHODS: From the pilot study for the European DISCHARGE trial, we analysed data from 24 sites including 1263 patients (45.9% women, 61.1 ± 11.3 years) who were clinically referred for invasive coronary angiography (ICA; 617 patients) or coronary computed tomography angiography (CTA; 646 patients). Prior to the procedures, patients completed HRQoL questionnaires: the Short Form (SF)-12v2, the EuroQoL (EQ-5D-3 L) and the Hospital Anxiety and Depression Scale. RESULTS: Fifty-five percent of ICA and 35% of CTA patients had typical angina, 23 and 33% had atypical angina, 18 and 28% had non-anginal chest discomfort and 5 and 5% had other chest discomfort, respectively. Patients with typical angina had the poorest physical functioning compared to the other angina groups (SF-12 physical component score; 41.2 ± 8.8, 43.3 ± 9.1, 46.2 ± 9.0, 46.4 ± 11.4, respectively, all age and gender-adjusted p < 0.01), and highest anxiety levels (8.3 ± 4.1, 7.5 ± 4.1, 6.5 ± 4.0, 4.7 ± 4.5, respectively, all adjusted p < 0.01). On all other measures, patients with typical or atypical angina had lower HRQoL compared to the two other groups (all adjusted p < 0.05). HRQoL did not differ between patients with and without obstructive CAD while women had worse HRQoL compared with men, irrespective of age and angina type. CONCLUSIONS: Prior to a diagnostic procedure for stable chest pain, HRQoL is associated with chest pain characteristics, but not with obstructive CAD, and is significantly lower in women. TRIAL REGISTRATION: Clinicaltrials.gov, NCT02400229.


Assuntos
Angina Pectoris/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Qualidade de Vida , Idoso , Angina Pectoris/classificação , Angina Pectoris/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Distribuição por Sexo , Inquéritos e Questionários
6.
Eur Radiol ; 30(4): 1997-2009, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31844958

RESUMO

OBJECTIVE: To implement detailed EU cardiac computed tomography angiography (CCTA) quality criteria in the multicentre DISCHARGE trial (FP72007-2013, EC-GA 603266), we reviewed image quality and adherence to CCTA protocol and to the recommendations of invasive coronary angiography (ICA) in a pilot study. MATERIALS AND METHODS: From every clinical centre, imaging datasets of three patients per arm were assessed for adherence to the inclusion/exclusion criteria of the pilot study, predefined standards for the CCTA protocol and ICA recommendations, image quality and non-diagnostic (NDX) rate. These parameters were compared via multinomial regression and ANOVA. If a site did not reach the minimum quality level, additional datasets had to be sent before entering into the final accepted database (FADB). RESULTS: We analysed 226 cases (150 CCTA/76 ICA). The inclusion/exclusion criteria were not met by 6 of the 226 (2.7%) datasets. The predefined standard was not met by 13 of 76 ICA datasets (17.1%). This percentage decreased between the initial CCTA database and the FADB (multinomial regression, 53 of 70 vs 17 of 75 [76%] vs [23%]). The signal-to-noise ratio and contrast-to-noise ratio of the FADB did not improve significantly (ANOVA, p = 0.20; p = 0.09). The CTA NDX rate was reduced, but not significantly (initial CCTA database 15 of 70 [21.4%]) and FADB 9 of 75 [12%]; p = 0.13). CONCLUSION: We were able to increase conformity to the inclusion/exclusion criteria and CCTA protocol, improve image quality and decrease the CCTA NDX rate by implementing EU CCTA quality criteria and ICA recommendations. KEY POINTS: • Failure to meet protocol adherence in cardiac CTA was high in the pilot study (77.6%). • Image quality varies between sites and can be improved by feedback given by the core lab. • Conformance with new EU cardiac CT quality criteria might render cardiac CTA findings more consistent and comparable.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes
7.
Rev Port Cardiol (Engl Ed) ; 38(11): 779-785, 2019 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-32057522

RESUMO

INTRODUCTION: Coronary intravascular ultrasound (IVUS) is increasingly important in catheterization laboratories due to its positive prognostic impact. This study aims to characterize the use of IVUS in percutaneous coronary intervention (PCI) in Portugal. METHODS: A retrospective observational study was performed based on the Portuguese Registry on Interventional Cardiology of the Portuguese Society of Cardiology. The clinical and angiographic profiles of patients who underwent PCI between 2002 and 2016, the percentage of IVUS use, and the coronary arteries assessed were characterized. RESULTS: A total of 118 706 PCIs were included, in which IVUS was used in 2266 (1.9%). Over time, use of IVUS changed from none in 2002 to generally increasing use from 2003 (0.1%) to 2016 (2.4%). The age of patients in whom coronary IVUS was used was similar to that of patients in whom IVUS was not used, but in the former group there were fewer male patients, and a higher prevalence of cardiovascular risk factors (hypertension, hypercholesterolemia and diabetes), previous myocardial infarction, previous PCI, multivessel coronary disease, C-type or bifurcated coronary lesions, and in-stent restenosis. IVUS was used in 54.8% of elective PCIs and in 19.15% of PCIs of the left main coronary artery. CONCLUSION: Coronary IVUS has been increasingly used in Portugal since 2003. It is used preferentially in elective PCIs, and in patients with higher cardiovascular risk, with more complex coronary lesions and lesions of the left main coronary artery.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Intervenção Coronária Percutânea , Ultrassonografia de Intervenção , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Portugal , Estudos Retrospectivos , Fatores de Risco
8.
Rev Esp Cardiol (Engl Ed) ; 72(6): 449-455, 2019 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29754808

RESUMO

INTRODUCTION AND OBJECTIVES: Many patients with nonvalvular atrial fibrillation are still left without protection due to a contraindication for anticoagulants. This study aimed to establish the occurrence of stroke and major bleeding events in patients with nonvalvular atrial fibrillation and left atrial appendage closure with long-term follow-up and to explore the factors associated with higher long-term mortality. METHODS: Analysis of a multicenter single cohort prospectively recruited from 2009 to 2015. Thromboembolic and bleeding events were compared with those expected from CHA2DS2-VASc and HAS-BLED scores. Multivariate analysis examined variables associated with mortality during follow-up. RESULTS: A total of 598 patients (1093 patient-years) with a contraindication for anticoagulants were recruited (median 75.4 years). The success rate of left atrial appendage closure device implantation was 95.8%. Thirty patients (5%) experienced periprocedural complications. The rate of events (per 100 patient-years) during follow-up (mean 22.9 months; median 16.1 months) was as follows: death 7.0%; ischemic stroke 1.6% (vs 8.5% expected according to CHA2DS2-VASc; P < .001); intracranial hemorrhage 0.8%; gastrointestinal bleeding 3.2%; severe bleeding 3.9% (vs 6.3% expected by HAS-BLED, P = .002). These results were improved in the subgroup of 176 patients with follow-up > 24 months (mean follow-up 46.6 months, 683 patient-years) for severe bleeding 2.6% (vs 6.3% expected by HAS-BLED, P < .033). The factors significantly associated with higher mortality were age (HR, 1.1), intracranial hemorrhage (HR, 6.8), and stroke during follow-up (HR, 2.7). CONCLUSIONS: Left atrial appendage closure significantly reduced the incidence of stroke and bleeding events and the benefit was maintained. Intracranial hemorrhage, age and stroke were associated with higher mortality.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Sistema de Registros , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Masculino , Portugal/epidemiologia , Estudos Prospectivos , Espanha/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
10.
BMC Cardiovasc Disord ; 18(1): 69, 2018 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-29699478

RESUMO

BACKGROUND: We aimed to evaluate the impact of thrombus aspiration (TA) during primary percutaneous coronary intervention (P-PCI) in 'real-world' settings. METHODS: We performed a retrospective study, using data from the National Registry of Interventional Cardiology (RNCI 2006-2012, Portugal) with ST-elevation myocardial infarction (STEMI) patients treated with P-PCI. The primary outcome, in-hospital mortality, was analysed through adjusted odds ratio (aOR) and 95% confidence intervals (95%CI). RESULTS: We assessed data for 9458 STEMI patients that undergone P-PCI (35% treated with TA). The risk of in-hospital mortality with TA (aOR 0.93, 95%CI:0.54-1.60) was not significantly decreased. After matching patients through the propensity score, TA reduced significantly the risk of in-hospital mortality (OR 0.58, 95%CI:0.35-0.98; 3500 patients). CONCLUSIONS: The whole cohort data does not support the routine use of TA in P-PCI, but the results of the propensity-score matched cohort suggests that the use of selective TA may improve the short-term risks of STEMI.


Assuntos
Trombose Coronária/cirurgia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Trombectomia , Idoso , Trombose Coronária/diagnóstico , Trombose Coronária/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Portugal , Fatores de Proteção , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Trombectomia/efeitos adversos , Trombectomia/mortalidade , Fatores de Tempo , Resultado do Tratamento
11.
Heart ; 104(10): 828-834, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29352008

RESUMO

OBJECTIVE: We aimed to analyse the incidence of prosthesis-patient mismatch (PPM) and elevated gradients after aortic valve in valve (ViV), and to evaluate predictors and associations with clinical outcomes of this adverse event. METHODS: A total of 910 aortic ViV patients were investigated. Elevated residual gradients were defined as ≥20 mm Hg. PPM was identified based on the indexed effective orifice area (EOA), measured by echocardiography, and patient body mass index (BMI). Moderate and severe PPM (cases) were defined by European Association of Cardiovascular Imaging (EACVI) criteria and compared with patients without PPM (controls). RESULTS: Moderate or greater PPM was found in 61% of the patients, and severe in 24.6%. Elevated residual gradients were found in 27.9%. Independent risk factors for the occurrence of lower indexed EOA and therefore severe PPM were higher gradients of the failed bioprosthesis at baseline (unstandardised beta -0.023; 95% CI -0.032 to -0.014; P<0.001), a stented (vs a stentless) surgical bioprosthesis (unstandardised beta -0.11; 95% CI -0.161 to -0.071; P<0.001), higher BMI (unstandardised beta -0.01; 95% CI -0.013 to -0.007; P<0.001) and implantation of a SAPIEN/SAPIEN XT/SAPIEN 3 transcatheter device (unstandardised beta -0.064; 95% CI -0.095 to -0.032; P<0.001). Neither severe PPM nor elevated gradients had an association with VARC II-defined outcomes or 1-year survival (90.9% severe vs 91.5% moderate vs 89.3% none, P=0.44). CONCLUSIONS: Severe PPM and elevated gradients after aortic ViV are very common but were not associated with short-term survival and clinical outcomes. The long-term effect of poor post-ViV haemodynamics on clinical outcomes requires further evaluation.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica , Complicações Pós-Operatórias , Reoperação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Índice de Massa Corporal , Ecocardiografia/métodos , Feminino , Humanos , Incidência , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Reoperação/instrumentação , Reoperação/métodos , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
13.
Ann Transl Med ; 5(15): 307, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28856147

RESUMO

Anti-cardiac troponin antibodies have been studied in different types of clinical diseases and in healthy populations. A systematic review of published data on anti-troponin antibodies was carried out (search performed on PubMed, ISI Web of Knowledge and Scopus databases). From title and abstract analysis, thirty-three articles were included that met the pre-specified criteria; after full-text analysis, nine articles were excluded. Most studies assessed anti-troponin I antibodies. The prevalence of anti-cardiac troponin antibodies in healthy individuals ranged from 0.0% to 20.0%. The prevalence of anti-troponin I autoantibodies in dilated cardiomyopathy (DCM) ranged from 7.0% to 22.2%. Other conditions under study were myocardial infarction, ischemic cardiomyopathy (ICM), peripartum cardiomyopathy (PPCM), Chagas disease, Emery-Dreifuss muscular dystrophy (EDMD) and renal transplantation. In the different patient populations studied, anti-cardiac troponin antibodies have been shown to be either positively or negatively associated with prognostic and clinical features. In what concerns a possible value as biomarkers, these assays have not emerged up to the present moment as important aids for practical clinical decisions in cardiac or other types of patients. In what concerns pathophysiology, anti-cardiac troponin autoantibodies may play a role in different diseases. It can be speculated that these antibodies could be involved in perpetuating some degree of cardiac injury after an event, such as myocardial infarction or PPCM.

14.
Rev Port Cardiol ; 36(7-8): 489-494, 2017.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28673782

RESUMO

INTRODUCTION AND OBJECTIVES: Paravalvular leak (PVL) is a possible complication after prosthetic valve implantation. PVL can cause significant symptoms of congestive heart failure and/or hemolysis. Medical therapy is palliative and reoperation has a high mortality rate. Percutaneous transcatheter closure is a promising alternative for symptomatic patients at high surgical risk. We aim to review the efficacy and safety of percutaneous PVL closure in a consecutive series of patients referred to our center. METHODS: We performed a retrospective analysis of clinical and technical procedural data of patients referred to our center for percutaneous PVL closure between January 2009 and November 2015. RESULTS: Twenty procedures were performed in 18 patients under general anesthesia and under transesophageal echocardiographic and radiographic guidance. Fourteen mitral PVLs were successfully treated in 13 patients and one aortic PVL in one patient. Most (eight) of the PVLs closed were in mitral bioprostheses. Two patients underwent a second intervention, which was technically successful in one. Technical success was achieved in 15 (75%) of the procedures. At discharge, median NYHA functional class decreased by one and hemolytic anemia decreased from seven cases (38.9%) to two (11.1%). Two patients had minor bleeding at the femoral vascular access site. Survival rates at six, 12 and 24 months were 77.8%, 77.8% and 61.1%, respectively. CONCLUSIONS: In our experience, percutaneous PVL closure was overall effective and safe. The procedure is complex and a second intervention may be necessary. Percutaneous PVL closure may be a feasible alternative for selected symptomatic patients at high surgical risk refractory to medical therapy.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
16.
EuroIntervention ; 13(Z): Z55-Z58, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28504232

RESUMO

The aim of the present paper is to report trends in Portuguese interventional cardiology from 2010 to 2015. We studied data from the prospective multicentre Portuguese National Registry of Interventional Cardiology (RNCI) to analyse percutaneous coronary intervention (PCI) procedures and structural heart interventions from 2010 to 2015. A total of 73,977 PCIs and 780 transcatheter aortic valve implants were performed during the study period. Since 2010 there has been a 60% increase in PCI procedures and a twofold increase in primary angioplasty rates reaching 316 per million population. Significant PCI trends were observed, notably the increase of radial access, a reduction in restenosis indications, as well as an increase in stent use, including DES, in imaging and in functional techniques. Importantly, there was a fourfold increase in the TAVI rates reaching 29 per million population.


Assuntos
Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos , Angiografia Coronária , Infarto do Miocárdio/cirurgia , Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Coração , Humanos , Portugal , Sistema de Registros
17.
Eur Radiol ; 27(7): 2957-2968, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27864607

RESUMO

OBJECTIVES: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninvasive test for detection and exclusion of coronary artery disease (CAD). To investigate the comparative effectiveness of CT and ICA, we designed the European pragmatic multicentre DISCHARGE trial funded by the 7th Framework Programme of the European Union (EC-GA 603266). METHODS: In this trial, patients with a low-to-intermediate pretest probability (10-60 %) of suspected CAD and a clinical indication for ICA because of stable chest pain will be randomised in a 1-to-1 ratio to CT or ICA. CT and ICA findings guide subsequent management decisions by the local heart teams according to current evidence and European guidelines. RESULTS: Major adverse cardiovascular events (MACE) defined as cardiovascular death, myocardial infarction and stroke as a composite endpoint will be the primary outcome measure. Secondary and other outcomes include cost-effectiveness, radiation exposure, health-related quality of life (HRQoL), socioeconomic status, lifestyle, adverse events related to CT/ICA, and gender differences. CONCLUSIONS: The DISCHARGE trial will assess the comparative effectiveness of CT and ICA. KEY POINTS: • Coronary artery disease (CAD) is a major cause of morbidity and mortality. • Invasive coronary angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest probability for CAD.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Avaliação de Resultados em Cuidados de Saúde , Tomografia Computadorizada por Raios X/métodos , Idoso , Doença da Artéria Coronariana/economia , Análise Custo-Benefício , Europa (Continente) , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Qualidade de Vida , Estudos Retrospectivos
18.
Front Cardiovasc Med ; 3: 32, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27703967

RESUMO

Thoracic endovascular aortic repair (TEVAR) is increasingly used in the treatment of acute type B aortic dissection. Type Ia endoleaks are a common complication of the procedure, but its clinical significance and the best treatment strategy remain poorly defined. We present a case of a type Ia endoleak following TEVAR in the treatment of acute type B aortic dissection. Chimney technique approach was used in an attempt to seal the endoleak. Although technical success was suboptimal, the patient remained clinically stable and event free. Data regarding the natural course and management of type Ia endoleaks following TEVAR for aortic dissection are sparse. Future research is required to establish the clinical and technical determinants of the need to treat these endoleaks and the best treatment strategy.

19.
Echocardiography ; 33(10): 1617-1618, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27357905

RESUMO

We describe a rare case of multiple myocardial crypts with atypical septal localization, evaluated with multimodality imaging. Although myocardial crypts seem to be more prevalent in hypertensive and hypertrophic cardiomyopathy patients, they are also occasionally found in apparently normal patients. Their clinical significance remains poorly understood.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Imagem Multimodal/métodos , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Doenças Raras/diagnóstico por imagem
20.
Rev Port Cardiol ; 35(7-8): 395-404, 2016.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27396628

RESUMO

INTRODUCTION AND OBJECTIVES: The aim of the present paper was to report trends in coronary angioplasty for the treatment of ST-elevation myocardial infarction (STEMI) in Portugal. METHODS: Prospective multicenter data from the Portuguese National Registry of Interventional Cardiology (RNCI) and official data from the Directorate-General for Health (DGS) were studied to analyze percutaneous coronary intervention (PCI) procedures for STEMI from 2002 to 2013. RESULTS: In 2013, 3524 primary percutaneous coronary intervention (p-PCI) procedures were performed (25% of all procedures), an increase of 315% in comparison to 2002 (16% of all interventions). Between 2002 and 2013 the rate increased from 106 to 338 p-PCIs per million population per year. Rescue angioplasty decreased from 70.7% in 2002 to 2% in 2013. During this period, the use of drug-eluting stents grew from 9.9% to 69.5%. After 2008, the use of aspiration thrombectomy increased, reaching 46.7% in 2013. Glycoprotein IIb-IIIa inhibitor use decreased from 73.2% in 2002 to 23.6% in the last year of the study. Use of a radial approach increased steadily from 8.3% in 2008 to 54.6% in 2013. CONCLUSION: During the reporting period there was a three-fold increase in primary angioplasty rates per million population. Rescue angioplasty has been overtaken by p-PCI as the predominant procedure since 2006. New trends in the treatment of STEMI were observed, notably the use of drug-eluting stents and radial access as the predominant approach.


Assuntos
Stents Farmacológicos/tendências , Intervenção Coronária Percutânea/tendências , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Idoso , Stents Farmacológicos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/estatística & dados numéricos , Portugal , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...